WINISO®
Calculating heat flows, thermal bridges, isotherms and Uf-values according to EN ISO 10077-2:2017.
Imported CAD files can be analysed automatically and failures in the drawing are removed by the sofware. Therefore complex constructions and constructionsystems can be calculated within a short time. Due to the integrated FEM calculating engine, results are determined very precisely.
Features
- Highly automated geometry processing of CAD files in .dxf and .dwg format
- Detailed geometrics and efficient computation of inclinations and radii
- Automated material assignment based on CAD layers
New solver and calculating enginge with automated FEM-mesh generation - Calculation according to „Radiosity-Model“ (new cavity model according to EN ISO 10077-2:2017) and equivalent thermal conductivity (EN ISO 10077-2:2012/2017)
- Simple definition of foils, coatings and surface characteristics by polylines
- Various mixable gas filling of the cavity according to EN 673
- Automatically determined Uf-values of windows and facade profiles
- Automated Psi-values of thermal bridges and insulating glass spacer according to EN ISO 10211 and EN ISO 10077-2
- Ug-values of insulating glass units according to EN 673
- U-value computation of any construction
- Calculation of isotherms, surface temperatures and temperature factor
More Features
- Three-dimensional
The profiles can be displayed in WINISO® as a 3D view. In the 3D evaluation …
- Humidity
The following evaluation modes are available with the “Humidity” add-on
- Uf-Value
The U value of a frame, called Uf value, indicates the heat transfer through the
News about WINISO® Recently we have received confirmation from the testing institute ift Rosenheim that our software WINISO® … We have received confirmation from the ift Rosenheim testing institute that our WINISO® software has …
More program news... Validation of the WINISO® software
ift certificate for the software WINISO®